Filter Results By:

Products

Applications

Manufacturers

High Voltage

electric power transmission is > 35,000 volts and for safety AC > 1000 and DC > 1,500. AKA: HV

See Also: High Voltage Switching, High Voltage Meters, High Voltage Detectors, High Voltage Programmable Power Supplies, HV


Showing results: 1921 - 1935 of 2454 items found.

  • Current Source-Sink D/A Converters

    Analog Devices Inc.

    Analog Devices’ current source D/A converters (DACs) portfolio is ideal for photonics control applications where low current noise density, low dropout voltage, and high power efficiency, in addition to high channel density, is critical to system performance. The flexibility of the configurable current source D/A converter outputs, and 300 mA current delivery, make them suitable for resistive heaters and proportional solenoid drive.

  • Dual Channel Clock Driver Card

    PI-41400 - Pulse Instruments

    The PI-41400 is a dual channel Clock Driver card capable of operating up to 190 MHz into a 50-ohm load and up to 80 MHz at an amplitude of 8 volts into a 1-megohm load. Into a high impedance load the output voltage range is from a –3 volts to 8 volts with the output pulse amplitude ranging from 0.5 V to 9 V. When driving a 50 load the voltage range is –1.5 volts to 4.5 volts with the output pulse amplitude ranging from 0.25 V to 4.5 V. The rise and fall times of the output pulse are variable from 1.2 ns to 9 ns into a 50-ohm load and <5 ns to 9 ns into a HiZ load. The output pulse amplitude and the load being driven determine the range of variability. The driver output can be set for tri-state operation and the output polarity can be set for ‘Normal’ or ‘Inverted’ operation through software.

  • Four Channel Clock Driver Card

    PI-41401 - Pulse Instruments

    The PI-41401 is a four channel Clock Driver card capable of operating up to 140 MHz at 3V and 100 MHz at 5V amplitudes into a 50 Ohm load. The PI-41401 has a clock rate of 90 MHz at an amplitude of 5 volts into a 1-MOhm load. Into a high impedance load the output voltage range is from –5 volts to +8 volts with the pulse amplitude ranging from 0V to 9V. When driving a 50 load the voltage range is –2.5 volts to 4.0 volts with the pulse amplitude ranging from effectively 0V to 4.5V. Each channel has a common edgespeed control to vary the rising and falling edges of the output waveform. The adjustable slew rate range, for any amplitude, is the minimum edgespeed of that amplitude times 5. The output pulse amplitude and the load being driven determine the range of variability.

  • 3-Phase Programmable AC Source

    61700 - Chroma Systems Solutions, Inc.

    Power: 1500VA, 3 (61701); 3000VA, 3 (61702); 4500VA, 3 (61703); 6000VA, 3 (61704); 12000VA, 3 (61705)Voltage: 0~150V/0~300VFrequency: 15~1.2KHzPhase angle: 0~360Built-in PFC, provides input power factor over 0.98Advanced PWM technology delivers high power density in a compact rack-mountable packageBuilt-in output isolation relaysAC+DC output modeProgrammable slew rate setting for changing voltage (optional function)Turn on, turn off phase angle controlUser-definable power-on statusPower line disturbance (PLD) simulation capability (optional function)Comprehensive measurement capability: V, Irms, Ipk, I inrush, P, PF, CF of current etc.Programmable r.m.s. current limitFull protection: OP, OC, OV and OT protectionGPIB and RS-232C interface (optional)Easy-use software for operation

  • Earth Tester

    TAURUS PRECIOHM ET - Taurus Powertronics Systems

    The TAURUS PRECIOHM ET is one of the specially designed products by TAURUS to measure earth resistivity and earth resistance in a power station. These tests are performed based on 4 point (Wenner) and 3 point (fall of potential) methods respectively. All electrical equipment in the substation and power stations are electrically connected to station earth mat with earth electrodes. The earth electrode ensures that in the event over voltage on the system due to system fault or lighting discharges etc., the parts of the equipment which are normally ”dead” as far as voltages are concerned; do not attain dangerously high potentials. An earth electrode will only be effective so long it has a low resistance to the earth and can carry large currents without deteriorating. Thus the resistance of earth electrode should be low to give good protection and it must be continuously measured and monitored in all the substations and power stations.

  • Manual Flying Probe Test Systems

    atg Luther & Maelzer

    They provide flexible measurement technologies like Kelvin and high voltage tests in combination with low tooling costs. atg Luther & Maelzer offers a wide range of different systems starting from standard systems with 8 heads up to oversized systems with 24 test heads.

  • HV Rotary Switches

    B-1003 - ROSS ENGINEERING CORPORATION

    A key feature of our rotary switches is their simple mechanical design which results in conservative stress levels for trouble-free, long life use.  In addition, each rotary switch has a reinforced chassis design utilizing G-10 or G-11 fire retardant anti-tracking coated epoxy glass insulation.  G-7 silicone glass is used for special applications where RF or high temperatures are involved.  Heavy duty contacts, specifically designed to minimize corona in the Ross rotaries, are made of highly conductive yet weld resistant alloy with high contact closing force.  This high force gives our rotary switches high momentary current capability and a reputation for their ability to withstand high shock and vibration as well as other severe environmental conditions.  Ratings to 150kV, to 200A.  When immersed in insulating oil, fluid or gas, the voltage withstand value is at least doubled and the interrupt capability is much greater.  In a gas atmosphere, no modification is required. However, immersion in oil or fluid may require modification in some cases, at an extra cost (optional).  Each unit is either manually or electrically operated.  One SPDT contact is standard on most units.  The auxiliary contact is used as an interlock for protection against "Switching Hot".

  • LVDS (Low Voltage Differential Signaling) Drivers and Receivers

    Analog Devices Inc.

    LVDS (Low Voltage Differential Signaling) Drivers and Receivers from Analog Devices offers designers robust, high speed signaling for single-ended to differential solutions for point-to-point applications. Our selection of products conform to the TIA/EIA-644 LVDS standard and contain the first LVDS transceivers to meet 8 kV IEC ESD performance standards - important for robust, interboard applications where the connectors can be exposed to more harsh electrostatic environments. Companion differential line receivers and differential line drivers support up to 600Mbps. LVDS greatly improves noise immunity and minimizes emissions for high speed point-to-point data transmission and is a low power alternative to emitter-coupled logic (ECL) or positive emitter-coupled logic (PECL) signaling.

  • PXI/PXIe High Resolution Waveform Digitizer Family

    PXD(e)721x - VX Instruments GmbH

    The PXD(e)721x High Resolution Digitizer- Family features up to two 100MS/s simultaneously sampled input channels with 16 Bit resolution, input voltages up to ±60V and a bandwidth of 50MHz (100MHz with option DBW).Every digitizer channel has its own 2MB memory which allows up to 1 million samples. Depending on the amount of channels and the isolated option, the digitizers are built into a compact 3U PXI device for 1 or 2 slots. All isolated devices have a high common mode rejection ratio (CMRR). A great number of trigger capabilities results in multiple instrument and channel synchronization possibilities.Data can be acquired before and after the trigger event with a programmable sample counter, that controls the number of data points.

  • Dry Arc Resistance Tester

    SCR ELEKTRONIKS

    Dry Arc Resistance Tester is designed to conduct high voltage,low current Arc Resistance test on solid electrical insulation material as per:ASTM standard D495-99 (2004) and UL 746A. Why Arc Resistance Test? Many Cases of insulator failure are due to deterioration of its surface because of sustained electrical discharge or Arc. This test method is intended to test the resistance of insulating material when a high -Voltage low -current Arc close to the surface of insulation, intending to form a conducting path therein or in causing the material to become conducting due to decomposition and erosion.AdvantagesThis Test ensures that your products meet high standards of quality & safety. This product is meant for all Switchgears/ insulator/ Polymer/ electro plastic manufacturers and manufacturers who use insulators in their products e.g. Wiring Accessories, Appliances, HT/LT line insulators etc.

  • PXI 40Amp 14Volt 2xSPST Automotive Relay

    40-180-001 - Pickering Interfaces Ltd.

    Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDCThe 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.

  • PXI 20Amp 28Volt 2xSPST Automotive Relay

    40-180-011 - Pickering Interfaces Ltd.

    Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDC.The 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.

  • PXI 40Amp 14Volt 4xSPST Automotive Relay

    40-180-101 - Pickering Interfaces Ltd.

    Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDC. The 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.

  • PXI 20Amp 28Volt 2xSPDT Automotive Relay

    40-181-011 - Pickering Interfaces Ltd.

    Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDC. The 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.

  • PXI 20Amp 28Volt 4xSPST Automotive Relay

    40-180-111 - Pickering Interfaces Ltd.

    Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDC.The 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.

Get Help